The DOE test procedure has been updated to be more representative of installations in today’s homes and will be used to determine product ratings. The testing procedure change will increase the external static pressure by a factor of 5 to better reflect field conditions. This new system of measurement will apply to all single-phase air conditioners and heat pumps <65k BTU/HR.
“SEER2” stands for Seasonal Energy Efficiency Ratio 2. Specifically, SEER2 is the total heat removed from the conditioned space during the annual cooling season. The new M1 testing procedure will increase systems' external static pressure by a factor of five to better reflect field conditions of installed equipment. With this change, new
“SEER2” stands for Seasonal Energy Efficiency Ratio 2. Specifically, SEER2 is the total heat removed from the conditioned space during the annual cooling season. The new M1 testing procedure will increase systems' external static pressure by a factor of five to better reflect field conditions of installed equipment. With this change, new nomenclature will be used to denote M1 ratings (including EER2 and HSPF2).
To meet new testing requirements, manufacturers are redesigning system components. In fact, all air conditioning and heat pump systems must be renovated by January 1, 2023, even if they meet current SEER ratings. In addition, matching components such as furnaces and air handlers will be redesigned to meet changes in the airflow setpoint
To meet new testing requirements, manufacturers are redesigning system components. In fact, all air conditioning and heat pump systems must be renovated by January 1, 2023, even if they meet current SEER ratings. In addition, matching components such as furnaces and air handlers will be redesigned to meet changes in the airflow setpoint. Depending on your region, additional field install equipment, such as Thermal Expansion Valves (TXVs), may also be required.
The goal of new SEER2 testing procedures is to better represent external conditions seen in the field. Current SEER testing does not accurately emulate the influence of ductwork and external static pressure on HVAC products. Because of this, it is not often representative of real-world applications. By increasing systems’ external static
The goal of new SEER2 testing procedures is to better represent external conditions seen in the field. Current SEER testing does not accurately emulate the influence of ductwork and external static pressure on HVAC products. Because of this, it is not often representative of real-world applications. By increasing systems’ external static pressure from current SEER (0.1 in. of water) to SEER2 (0.5 in. of water), new M1 testing procedures more accurately reflect current field conditions.
The change from SEER to SEER2 has made inventory management in the South and Southwest regions more complicated in ensuring existing inventory that is sold is compliant with the new efficiency standards. Compliance with the 2023 standards is based on the least efficient combination of indoor and outdoor units, commonly referred to as the
The change from SEER to SEER2 has made inventory management in the South and Southwest regions more complicated in ensuring existing inventory that is sold is compliant with the new efficiency standards. Compliance with the 2023 standards is based on the least efficient combination of indoor and outdoor units, commonly referred to as the coil-only rating. This rating is listed on the equipment's energy guide label. If a range is given, the least efficient rating should be used. See the below explanation for further information.
For split system AC equipment manufactured prior to December 31, 2022, and installed in the South or Southwest Regions after January 1, 2023:
Effective January 1, 2023, cooling products will be subject to regional minimum efficiencies. These efficiencies will depend on the region in which the product is installed. These units will need to adhere to the new testing measures and meet SEER2 rating requirements.
By January 1, 2023, all heat pumps will be subject to new national minimum efficiency levels. However, Existing 14.0 SEER heat pumps built prior to January 1, 2023 may still be sold and installed on or after January 1, 2023 in all regions. While single-packaged heat pumps may remain at 13.4 SEER2 (14.0 SEER) and 6.7 HSPF2 (8.0 HSPF), all
By January 1, 2023, all heat pumps will be subject to new national minimum efficiency levels. However, Existing 14.0 SEER heat pumps built prior to January 1, 2023 may still be sold and installed on or after January 1, 2023 in all regions. While single-packaged heat pumps may remain at 13.4 SEER2 (14.0 SEER) and 6.7 HSPF2 (8.0 HSPF), all split-system heat pumps must increase to 14.3 SEER2 (15.0 SEER) and 7.5 HSPF2 (8.8 HSPF). These units will need to adhere to the new testing measures and meet SEER2 rating requirements.
Current SEER ratings of single packaged units are 14.0 SEER and 8.0 HSPF. These will remain the same despite other regulatory changes. However, these units will still need to adhere to the new testing measures and meet SEER2 rating requirements of 13.4 SEER2 and 6.7 HSPF2.
Effective January 1, 2023, Mini-Split Air Conditioning products will be subject to regional minimum efficiencies. These efficiencies will depend on the region in which the product is installed. All Mini-Split Heat Pump products will be subject to national minimum efficiency levels. These units will need to adhere to the new testing measures and meet SEER2 rating requirements.
ANSWER: The newly revised test procedure is an entirely different way of calculating energy efficiency, thereby it has a different metric altogether. The new test procedure is more representative of system operation in typical home installations.
ANSWER: It varies by equipment type and region, but generally, minimum efficiencies are increasing by about 7–10%, or 1 SEER in the traditional system.
ANSWER: Just as it is today, the DOE relies on reporting of suspected violations by distributors, dealers and contractors. DOE investigates credible complaints and may assess penalties for violators.
ANSWER: Yes. Even if a product is moved to “production stopped” or “discontinued” in the AHRI directory, ratings are still available for a period of time after the status change.
ANSWER: No. The new efficiency standards and metrics do not apply to 3-phase equipment less than <65k BTU/HR at this time.
Add a footnote if this applies to your business